Description
Parameter Specification
Fiber Compatibility Single Mode
Central Wavelength (nm) 1310 & 1550 for Single Mode
Wavelength Tolerance (±) 20 nanometer
Dynamic range @ Max Wavelength 42 decibel
Event Dead Zone – Maximum 1 meter
Attenuation Dead Zone – Maximum 4 meter
Maximum Display Distance Range 300 kilometer
Pulse Width Range 5 to 20000 for Single Mode / Live Fiber Testing
Distance Measurement Accuracy (±) 0.75 meter
Reflection Detection Accuracy (±) ± 4 dB for Single Mode or better
Linearity (dB/dB) (±) 0.05
Sampling Points 128000
Measurement Time User Selectable 15 seconds to 180 seconds
DISPLAY / STORAGE
Display Colour Display, LCD, Daylight Readable Display, Touch Screen, Backlit Display
Display Size 5.6 inch
Connectivity Interface USB, RJ45
Internal Storage (OTDR Traces) 20000
External Storage / Memory Stick Slot Provided SD
External Storage Capacity (Inclusive in Scope of Supply) 0 Gigabyte
Integrated Stabilized Light Source Yes
Light Source Wave Length Same as OTDR
Modulation CW,270 Hz,1 kHz,2 kHz
Optical output power 6 dBm for Single Mode
Optical output port On OTDR Port
POWER SOURCE
Power Source Internal / Removable- Rechargeable Battery
Battery Chemistry, if Rechargeable Battery Li-Ion
Voltage of each Battery 7.4 Volt
Battery Capacity (mAh) 5000
Number of Batteries required for operation 1
Number of Batteries supplied (Inclusive in the Scope of Supply) 1
Operating Time per full charge (Minimum) 20 hour
Suitable Adapter to be supplied to make the equipment Work on 230 V ± 10 %, 50 Hz Yes
VISUAL FAULT LOCATOR (VFL) / VISUAL LIGHT SOURCE (VLS) FOR OTDR
Built-in Visual Fault Locator (VFL) / Visual Light Source (VSL) Yes
Wave Length Range (VFL/VSL) 650 nm ± 20 nm
Output Function (VFL/VSL) OFF,CW,Blink
Maximum Optical output power (Peak) (VFL/VSL) – dBm -3 dBm or more
Laser Safety of VFL/VSL as per IEC 60825-1 latest or equivalent international standard Class 2
POWER METER FOR OTDR
Built-in Power Meter Yes
Power Meter input port On OTDR Port
Wavelength Range 850 nm to 1650 nm
Modulation (Power Meter) CW,270 Hz,1 kHz,2 kHz
Minimum Power measurement range (dBm) -50
Maximum Power measurement range (dBm) 26
Accuracy (Power Meter) (±) 0.05 percent
Connector / Adapter End SC,FC,LC,ST
Connector Tip PC/UPC
OTDR Data Format sor
Laser Safety of OTDR as per IEC 60825-1 latest or equivalent international standard Class 1M (1310 nm), Class 1M (1550 nm)
Dimensions (mm × mm × mm) 227 × 160 × 70
Weight (with battery) 1.1 kilogram
“Salient Features (Select Applicable Features Only)” NA
Minimum Operating Temperature -10 degree Celsius
Maximum Operating Temperature 50 degree Celsius
Maximum Operating Humidity 95 percent
Accessories inclusive in the Scope of Supply (Select included Accessories Only) Suitable Fiber Inspection Probe,
Suitable LAN Cable,
DC vehicle battery charging adaptor (12 V),
Suitable VFL/VSL adapter,
Carry Case,
Manual
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “EW-SM4OTDR”