DETAILED SPECIFICTIONS | |
---|---|
DC Voltage Range | 1000 Volt |
DC Voltage Accuracy | 0.005 percent |
DC Voltage resolution | 0.001 milliVolt |
AC Voltage Range | 1000 Volt |
AC Voltage Accuracy | 1 percent |
AC Voltage resolution | 0.001 milliVolt |
DC Current Range | 10 Ampère |
DC Current Accuracy | 0.05 percent |
DC Current resolution | 0.001 milliAmpère |
AC Current Range | 10 Ampère |
AC Current Accuracy | 1 percent |
AC Current resolution | 0.001 milliAmpère |
Resistance Range | 40 megaOhm |
Resistance Accuracy | 0.08 percent |
Resistance resolution | 0.001 Ohm |
Capacitance Range ( Micro farad ) | 1 to 100 |
Capacitance Accuracy ( % ) | 1.5 |
Capacitance resolution ( nF ) | 0.001 |
Frequency Range ( KHz ) | 50 |
Frequency Accuracy ( % ) | 0.1 |
Frequency resolution ( Hz ) | 0.001 |
Temperature Range ( Degree C ) | -50 to 1000 |
Temperature Accuracy ( % ) | 1.5 |
Temperature resolution ( Degree C ) | 0.001 |
Type | Hand Held |
Display (Digits) | 4.5 |
Measurement Type | True RMS |
Counts | 50000 |
Continuity test and Diode test | Available |
Data logging | Available |
If Data Logging Feature is Available, Internal Memory | min. 5000 points/ 200 readings |
Computer Interface along with software | Available |
Dimensions ( mm X mm X mm ) | 300X200X80 |
Weight | 300 gram |
Other Features | NA |
Safety Rating | Category III 1000 V of IEC 61010. |
Safety Certification | UL,CE |
Power Requirements | 230 V +/-10% AC, 50 Hz +/- 3% through Adaptor |
if Battery Operated, then Type of Battery | Rechargeable |
if rechargeable , then chemistry of the battery | lithium ion |
if Non-rechargeable , then size of the battery / cell | AA |
number of non- rechargeable the battery / cell | 1 |
Voltage of rechargeable Battery | 100 |
capacity of rechargeable battery(milli Ampere Hour) | 50 |
Suitable charger / adaptor provided | YES |
Standard Accessories Supplied with the Equipment | NA |
Warranty | 1 year |
Minimum Operating Temperature | -10 degree Celsius |
Maximum Operating Condition | 50 degree Celsius |
Operating Humidity (RH) | 95 percent |
The equipment supplied with calibration certificate | YES |
conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:9000/part-3/section-5/1977 latest | Yes |
conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:9000/part- 2/section-4/1977 latest | Yes |
conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH | Yes |
Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification | Yes |
Test Report Number and date for the specification test | NA |
Name and address of the Lab for the specification test | NA |
Make | |
Model |
HAND HELD Digital Multimeter
Only logged in customers who have purchased this product may leave a review.
Reviews