HAND HELD Digital Multimeter

Product Enquiry
Category:
DETAILED SPECIFICTIONS
DC Voltage Range 1000 Volt
DC Voltage Accuracy 0.005 percent
DC Voltage resolution 0.001 milliVolt
AC Voltage Range 1000 Volt
AC Voltage Accuracy 1 percent
AC Voltage resolution 0.001 milliVolt
DC Current Range 10 Ampère
DC Current Accuracy 0.05 percent
DC Current resolution 0.001 milliAmpère
AC Current Range 10 Ampère
AC Current Accuracy 1 percent
AC Current resolution 0.001 milliAmpère
Resistance Range 40 megaOhm
Resistance Accuracy 0.08 percent
Resistance resolution 0.001 Ohm
Capacitance Range ( Micro farad ) 1 to 100
Capacitance Accuracy ( % ) 1.5
Capacitance resolution ( nF ) 0.001
Frequency Range ( KHz ) 50
Frequency Accuracy ( % ) 0.1
Frequency resolution ( Hz ) 0.001
Temperature Range ( Degree C ) -50 to 1000
Temperature Accuracy ( % ) 1.5
Temperature resolution ( Degree C ) 0.001
Type Hand Held
Display (Digits) 4.5
Measurement Type True RMS
Counts 50000
Continuity test and Diode test Available
Data logging Available
If Data Logging Feature is Available, Internal Memory min. 5000 points/ 200 readings
Computer Interface along with software Available
Dimensions ( mm X mm X mm ) 300X200X80
Weight 300 gram
Other Features NA
Safety Rating Category III 1000 V of IEC 61010.
Safety Certification UL,CE
Power Requirements 230 V +/-10% AC, 50 Hz +/- 3% through Adaptor
if Battery Operated, then Type of Battery Rechargeable
if rechargeable , then chemistry of the battery lithium ion
if Non-rechargeable , then size of the battery / cell AA
number of non- rechargeable the battery / cell 1
Voltage of rechargeable Battery 100
capacity of rechargeable battery(milli Ampere Hour) 50
Suitable charger / adaptor provided YES
Standard Accessories Supplied with the Equipment NA
Warranty 1 year
Minimum Operating Temperature -10 degree Celsius
Maximum Operating Condition 50 degree Celsius
Operating Humidity (RH) 95 percent
The equipment supplied with calibration certificate YES
conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:9000/part-3/section-5/1977 latest Yes
conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:9000/part- 2/section-4/1977 latest Yes
conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH Yes
Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification Yes
Test Report Number and date for the specification test NA
Name and address of the Lab for the specification test NA
Make  
Model  

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.