BASIC SPECIFICTIONS |
|
|---|---|
| DC Voltage Range | 600 |
| DC Voltage Accuracy | 0.05 |
| DC Voltage resolution | 0.1 |
| AC Voltage Range | 600 |
| AC Voltage Accuracy | 0.1 |
| AC Voltage resolution | 0.1 |
| DC Current Range | 3 |
| DC Current Accuracy | 0.05 |
| DC Current resolution | 1 |
| AC Current Range | 3 |
| AC Current Accuracy | 1 |
| AC Current resolution | 0.1 |
| Resistance Range | 50 |
| Resistance Accuracy | 1 |
| Resistance resolution | 0.1 |
| Capacitance Range ( Micro farad ) | 1 to 100 |
| Capacitance Accuracy ( % ) | 2.5 |
| Capacitance resolution ( nF ) | 1 |
| Frequency Range ( KHz ) | 50 |
| Frequency Accuracy ( % ) | 0.1 |
| Frequency resolution ( Hz ) | 0.1 |
| Temperature Range ( Degree C ) | -40 to 400 |
| Temperature Accuracy ( % ) | Â 1.5 |
| Temperature resolution ( Degree C ) | 1 |
| Type | Hand Held |
| Display (Digits) | 3.5 |
| Measurement Type | True RMS |
| Counts | 60000 |
| Continuity test and Diode test | Available |
| Data logging | Available |
| If Data Logging Feature is Available, Internal Memory | min. 2000 points/ 500 readings |
| Computer Interface along with software | NOT Available |
| Dimensions ( mm X mm X mm ) | 300X200X600 |
| Weight | 650 gram |
| Other Features | NA |
| Safety Rating | Category II 600 V of IEC 61010 |
| Safety Certification | CE |
| Power Requirements | Battery Operated |
| if Battery Operated, then Type of Battery | Non- Rechargeable (Alkaline) |
| if rechargeable , then chemistry of the battery | NA |
| if Non-rechargeable , then size of the battery / cell | 9-V rectangular battery |
| number of non- rechargeable the battery / cell | 1 |
| Voltage of rechargeable Battery | 100 Volt |
| capacity of rechargeable battery(milli Ampere Hour) | 50 |
| Suitable charger / adaptor provided | NA |
| Standard Accessories Supplied with the Equipment | NA |
| Warranty | 2 |
| Minimum Operating Temperature | -10 |
| Maximum Operating Condition | 50 |
| Operating Humidity (RH) | 80 |
| The equipment supplied with calibration certificate | YES |
| conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:9000/part- 3/section-5/1977 latest |
NO |
| conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:9000/part- 2/section-4/1977 latest |
NO |
| conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH | Yes |
| Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification | NA |
| Test Report Number and date for the specification test | NA |
| Name and address of the Lab for the specification test | NA |
Reviews (0)
Be the first to review “EW-HHMMKHZ50” Cancel reply


Reviews
There are no reviews yet.