| DETAILED SPECIFICTIONS | |
|---|---|
| DC Voltage Range | 1000 Volt |
| DC Voltage Accuracy | 0.005 percent |
| DC Voltage resolution | 0.001 milliVolt |
| AC Voltage Range | 1000 Volt |
| AC Voltage Accuracy | 1 percent |
| AC Voltage resolution | 0.001 milliVolt |
| DC Current Range | 10 Ampère |
| DC Current Accuracy | 0.05 percent |
| DC Current resolution | 0.001 milliAmpère |
| AC Current Range | 10 Ampère |
| AC Current Accuracy | 1 percent |
| AC Current resolution | 0.001 milliAmpère |
| Resistance Range | 40 megaOhm |
| Resistance Accuracy | 0.08 percent |
| Resistance resolution | 0.001 Ohm |
| Capacitance Range ( Micro farad ) | 1 to 100 |
| Capacitance Accuracy ( % ) | 1.5 |
| Capacitance resolution ( nF ) | 0.001 |
| Frequency Range ( KHz ) | 50 |
| Frequency Accuracy ( % ) | 0.1 |
| Frequency resolution ( Hz ) | 0.001 |
| Temperature Range ( Degree C ) | -50 to 1000 |
| Temperature Accuracy ( % ) | 1.5 |
| Temperature resolution ( Degree C ) | 0.001 |
| Type | Hand Held |
| Display (Digits) | 4.5 |
| Measurement Type | True RMS |
| Counts | 50000 |
| Continuity test and Diode test | Available |
| Data logging | Available |
| If Data Logging Feature is Available, Internal Memory | min. 5000 points/ 200 readings |
| Computer Interface along with software | Available |
| Dimensions ( mm X mm X mm ) | 300X200X80 |
| Weight | 300 gram |
| Other Features | NA |
| Safety Rating | Category III 1000 V of IEC 61010. |
| Safety Certification | UL,CE |
| Power Requirements | 230 V +/-10% AC, 50 Hz +/- 3% through Adaptor |
| if Battery Operated, then Type of Battery | Rechargeable |
| if rechargeable , then chemistry of the battery | lithium ion |
| if Non-rechargeable , then size of the battery / cell | AA |
| number of non- rechargeable the battery / cell | 1 |
| Voltage of rechargeable Battery | 100 |
| capacity of rechargeable battery(milli Ampere Hour) | 50 |
| Suitable charger / adaptor provided | YES |
| Standard Accessories Supplied with the Equipment | NA |
| Warranty | 1 year |
| Minimum Operating Temperature | -10 degree Celsius |
| Maximum Operating Condition | 50 degree Celsius |
| Operating Humidity (RH) | 95 percent |
| The equipment supplied with calibration certificate | YES |
| conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:9000/part-3/section-5/1977 latest | Yes |
| conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:9000/part- 2/section-4/1977 latest | Yes |
| conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH | Yes |
| Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification | Yes |
| Test Report Number and date for the specification test | NA |
| Name and address of the Lab for the specification test | NA |
| Make | |